MAE A6000SE modular combined
system is a very compact and versatile equipment for
24-channel/24-bit active and passive seismic PROSPECTIVEs, and
geoelectrical PROSPECTIVEs using both the four-terminal network
technique or the multi-electrode electrical tomography system.
The seismic or geoelectrical survey methods are easily selected from
the main menu of a touch-screen colour display. Upon choosing the
data acquisition system needed (single measurement or complete cycle),
data retrieval is automatically performed by the push of one button.
This seismograph main characteristic is the real 24-bit resolution
for each single channel; this is achieved thanks to MAE new 24-bit
data acquisition card, which uses an A/D 24-bit digital converter
for each of the seismograph entry channels. This peculiar
characteristic makes the A6000SE seismograph the ideal solution for
any active or passive seismic PROSPECTIVE, structural surveying and
inspections of buildings and infrastructure facilities (acquisition
of vibrations by accelerometers or low frequency seismic sensors,
tomographic surveys). |
|
Seismic Survey Methods
. Seismic refraction and reflection methods
. Down-hole, Cross-hole
. Seismic tomography
. Active and passive M.A.S.W. (microtremors), S.A.S.W.
Geoelectrical Survey Methods
. Self-potential method
. Apparent Resistivity
. Induced Polarization
. Chargeability (assessing pollution)
. SEV: Schlumberger/Wenner electrode array
. Electric tomography: Dipolo-dipolo/Wenner/Wenner-Schlumberger |
 |
|
24-bit Seismograph
Acquisition card resolution: 24-bit
Number of cable channels: from 12 to 24
Samples for each channel: 20,000
Sampling: from 50 to 15,000 sps
Band width: from 0 to 8 KHz
Maximum IN signal: 10V
Complete or partial display of the acquired data for each channel
Pre-data capture environmental noise analysis
Geophones automatic test function
Waves “Limit” and “Highlight” graphic functions
Real-time speed reading and first data collection functions |
Trigger and pre-trigger functions
Software-controlled filters settings/restrictions
Earth Resistivity Meter
Number of cable-connected electrodes: 16 to 256
50 to 600 Volt direct-current output
Built-in power generator: 60 Watt
Measurement resolution: 100 microvolt
External power unit (optional)
Terminal connections M-N, A-B for standard cable landing
Multi-electrode landing socket up to 256 electrodes |