A5000T Ground Thermal Response

The A5000T system is a compact instrument expressly dedicated to measuring the soil thermal conductivity, i.e. the property which governs the flow of heat through the soil. This type of inspection is usually performed prior to the laying of underground conduit pipes, or before building geothermal wells used for the thermal conditioning of buildings.
Thermal conductivity data can be obtained directly on-site through the instrument probe (120 cm long), or – when deeper inspections are requested – samples of compacted soil can be measured at the laboratory (the probe extension is removable).
The collected data can be directly processed on-site at the end of the acquisition phase, this latter being automatically controlled by the instrumentation. Data are both graphically and numerically expressed in watt/Metric Kelvin (watt = unit of power, meter = unit of distance, Kelvin = unit of temperature).
To perform this type of inspection it is necessary to drill a hole in the soil with a 20 mm dia. tool (drill not supplied). The probe has then to be inserted into the borehole and the probe tip driven slightly for about 20 cm so to get the best contact with the soil. The data acquisition procedure, which is automatically controlled by the instrument itself and which takes up a couple of minutes to be performed, can be triggered with just the push of one button. The graphical/numerical value obtained is then stored into an SD memory card to be processed later on.

Thermal conductivity of different kind of soil:
. dry rock: +/- 1.5 W/m K . gravel, sand (wet): 1.8 - 2.4 W/m K . granite: 3.4 W/m K

TECHNICAL SPECIFICATIONS
 Numerical and graphical display of the collected data
 Capacitive keyboard
 SD removable memory recording
 Battery condition shown on display
 Built-in clock with buffer battery
 Resolution: 24-bit
 Absorption: monitor OFF 40mA, monitor ON 90 mA
 Built-in battery life: monitor OFF 20 hours, monitor ON 8 hours
 Power supply: 12V built-in
 Battery pack: rechargeable, replaceable, AA batteries

 High impact strength polypropylene copolymers bag
 Operating temperature: from 0 to 60 °C
 0.1 to 6 W/m K, automatic graphic display (curve)
 Absolute measurement according to ASTM D 5334-92 standards
 Stainless-steel measurement probe: length 120 cm, dia. 18 mm
 Measurement point: length 17 mm, dia. 6.5 mm
 Soil drilling for measurements (18 mm dia. drill bit)
 Adjustable test length (300 seconds)
 Heater capacity below 5W
 Measurement temperature: from -10 to 130 degrees
 Measurement accuracy: +- 6% with good soil contact
 Dimensions: 270x120x246 mm
 Weight: 2.5 kg

[Prev] 1 2 [Next]